Quick Reference of Parameters, Alarms and Faults
0-14 | MW500
Parameter Description
Adjustable
Range
Factory
Setting
User
Setting
Properties Groups Page
P0741
Profibus Data Profile 0 = PROFIdrive
1 = Manufacturer
1
NET 17-4
P0742 Profibus Reading #3 0 to 1199 0 NET 17-4
P0743 Profibus Reading #4 0 to 1199 0 NET 17- 4
P0744 Profibus Reading #5 0 to 1199 0 NET 17-4
P0745 Profibus Reading #6 0 to 1199 0 NET 17- 4
P0746 Profibus Reading #7 0 to 1199 0 NET 17-5
P0747 Profibus Reading #8 0 to 1199 0 NET 17-5
P0750 Profibus Writing #3 0 to 1199 0 NET 17- 5
P0751 Profibus Writing #4 0 to 1199 0 NET 17-5
P0752 Profibus Writing #5 0 to 1199 0 NET 17-5
P0753 Profibus Writing #6 0 to 1199 0 NET 17- 5
P0754 Profibus Writing #7 0 to 1199 0 NET 17- 5
P0755 Profibus Writing #8 0 to 1199 0 NET 17- 5
P0918 Profibus Address 1 to 126 1 NET 17-5
P0922
Profibus Teleg. Sel. 2 = Std. Teleg. 1
3 = Telegram 103
4 = Telegram 104
5 = Telegram 105
6 = Telegram 106
7 = Telegram 107
8 = Telegram 108
2
NET 17-5
P0963
Profibus Baud Rate 0 = 9.6 kbit/s
1 = 19.2 kbit/s
2 = 93.75 kbit/s
3 = 187.5 kbit/s
4 = 500 kbit/s
5 = Not Detected
6 = 1500 kbit/s
7 = 3000 kbit/s
8 = 6000 kbit/s
9 = 12000 kbit/s
10 = Reserved
11 = 45.45 kbit/s
ro NET 17-5
P0967
Control Word 1 Bit 0 = ON
Bit 1 = No Coast Stop
Bit 2 = No Quick Stop
Bit 3 = Enable Operation
Bit 4 = Enable Ramp Generator
Bit 5 = Reserved
Bit 6 = Enable Setpoint
Bit 7 = Fault Acknowledge
Bit 8 = JOG 1 ON
Bit 9 = Reserved
Bit 10 = Control by PLC
Bit 11 to 15 = Reserved
ro NET 17-5
P0968
Status Word 1 Bit 0 = Ready to Switch ON
Bit 1 = Ready to Operate
Bit 2 = Operation Enabled
Bit 3 = Fault Present
Bit 4 = Coast Stop Not Active
Bit 5 = Quick Stop Not Active
Bit 6 = Switching ON Inhibited
Bit 7 = Warning Present
Bit 8 = Reserved
Bit 9 = Control Requested
Bit 10 to 15 = Reserved
ro NET 17-5
P1000 SoftPLC Status 0 = No Application
1 = Installing App.
2 = Incompatible App.
3 = Stoped App.
4 = App. Running
ro READ,
SPLC